Accuracy (DIN EN 837-1) Class 1.0
Case With bayonet ring, stainless steel 304 (1.4301)
Degree of Protection (DIN EN 60 529/IEC 529)
IP54
IP65 for model PG 100 StL and PG 160 (measuring spans ≥2.5 bar onwards)
Blow-out Device
Model PG 100: blow-out plug at the back of the case, Ø 1"
Model PG 160: blow-out device at the top of the case coverage
Case Ventilation
Model PG 100 StL: without ventilation, but with internal pressure compensation via pressure equalizing membrane
Model PG 160 StL: via blow-out device
Case Filling For model StL: glycerin
Nominal Case Size 100, 160, 250 mm (4, 6, 10")
Wetted Parts
Connection: stainless steel 316L (1.4404)
Bourdon tube: stainless steel 316L (1.4404), gas-shielded arc welding
≤40 bar (600 psi) C-form
≥60 bar (800 psi) helical form
1600 bar (20,000 psi) NiFe-alloy helical form
Case Configuration
Connection: screwed
Position of the connection:
bottom connection
lower back connection (r)
center back connection (rm)
Mounting device:
without
back flange for surface mounting (Rh)
front flange for panel mounting (Fr)
Pressure Ranges (DIN EN 837-1)
0 – 0.6 bar to 0 – 1600 bar (0 – 10 psi to 0 – 20,000 psi) for type –3
0 – 0.6 bar to 0 – 1000 bar (0 – 10 psi to 0 – 15,000 psi) for type –1
Pressure Limitations
Steady Pressure: full scale value
Cyclic Pressure: 90% of full scale value
Temporary: 150% of full scale value
Process Connection
G½ B (½" BSP)
½" NPT
M20 × 1.5
Window
Laminated safety glass
Instrument glass
Movement
Stainless steel
Brass/German silver
Dial Aluminum white, scale black
Pointer Aluminum black
Safety Category According to DIN EN 837-1 S1 pressure gauges with blow-out device NCS 100 (4")