Accuracy (DIN EN 837-1)
Class 1.6
Class 2.5 for pressure range 0 – 600 bar (0 – 10,000 psi)
Case With polished crimped-on ring, stainless steel 304 (1.4301)
Degree of Protection (DIN EN 60 529/IEC 529)
IP65 (≥10 bar)
IP54 (≤10 bar) with cut-off blow-out plug no. 19
Blow-out Device Blow-out plug at the top of the case coverage
Case Ventilation Via blow-out plug, ventilation required for internal pressure compensation for pressure ranges ≤10 bar, and also recommended for other pressure ranges if the operating conditions permit
Case Filling For model STL: glycerin
Nominal Case Size 40 mm (1½")
Wetted Parts
Connection: stainless steel 316L (1.4404)
Bourdon tube: stainless steel 316L (1.4404), gas-shielded arc welding
≤100 bar (1,500 psi) C-form
≥160 bar (2,000 psi) helical form
Case Configuration
Connection: welded
Position of the connection
bottom connection
center back connection (rm)
Mounting device
without
Mounting Device for center back connection:
front flange for panel mounting (rmFr)
U-clamp for panel mounting (rmBFr)
Pressure Ranges (DIN EN 837-1) 0 – 1 bar to 0 – 600 bar (0 – 15 psi to 0 – 10,000 psi)
Process Connection 1/8" NPT or 1/4" NPT
Window Instrument glass
Movement Stainless steel
Dial Aluminum white, scale black
Pointer Aluminum black
Safety Category According to DIN EN 837-1
S1 pressure gauges with blow-out device
S2 safety pressure gauge with window made of polycarbonate